Zirkon® DIS Total

(Total Chlorine)

Zirkon® DIS Total is an open potentiostatic sensor for measuring chlorine compounds.

Benefits

  • No exchange of membrane
  • No exchange of electrolyte
  • No delicate plastic membrane
  • Immune to air bubbles
Disinfection
Drinking Water
Ambient Conditions
  • Max. pressure: 6 bar at 20°C (87 psi at 68°F)
  • Min. conductivity: >150 µS/cm
  • Temperature: 0.. +50°C (32.. 122°F)
  • pH: 6-10
Versions
Type/Configuration Description Article number

239412500

DIS Total-Sensor: InnoDisk®, platinium ring, circon junction, Tepox Gel, M12 plug (swivel PG 13.5), 120 mm

S24135440K

Zirkon® DIS
(Free Chlorine)

Zirkon® DIS is a potentiostatic sensor for measuring Free Chlorine.

Benefits 

  • Low maintenance and robust 

  • Stable zero point 

  • Reliable measuring values 

  • Long operating life due to automatic sensor cleaning by ASR®

Applications
Disinfection
Drinking Water
Measuring Parameter
  • 0.. 1000 µg/l (ppb) 

  • 0.. 5.00/10.00 mg/l (ppm) 

  • 0.. 20.00 mg/l (ppm)

Measuring parameter and range are defined by the connected Kuntze instrument or system.

Ambient Conditions
  • Max. pressure: 10 bar at 20 °C (145 psi at 68 °F) 

  • Min. conductivity: > 150 µS/cm , with ASR > 200 µS/cm  

  • Temperature: -5.. +70 °C  (23.. 158 °F)

Versions
Type/Configuration Description Article number

231612500

DIS sensor: 2 gold rings, zircon junctions, Tepox gel, M12 plug (swivel PG 13.5), 120 mm

24135140K

231512110

DIS sensor: gold ring, zircon junction, Tepox gel, S8 plug (swivel PG 13.5), 80 mm

24135130K

Zirkon® DIS (Chlorine Dioxide)

Zirkon® DIS is a potentiostatic sensor for measuring Chlorine Dioxide.

Benefits 

  • Low maintenance and robust 

  • Stable zero point 

  • Reliable measuring values 

  • Long operating life due to automatic sensor cleaning by ASR®

Applications
Disinfection
Drinking Water
Measuring Parameter
  • 0.. 1000 µg/l (ppb) 

  • 0.. 5.00/10.00 mg/l (ppm) 

  • 0.. 20.00 mg/l (ppm)

 

Measuring parameter and range are defined by the connected Kuntze instrument or system.

Ambient Conditions
  • Max. pressure: 10 bar at 20 °C (145 psi at 68 °F) 

  • Min. conductivity: > 150 µS/cm , with ASR > 200 µS/cm  

  • Temperature: -5.. +70 °C  (23.. 158 °F)

Versions
Type/Configuration Description Article number

231612500

DIS sensor: 2 gold rings, zircon junctions, Tepox gel, M12 plug (swivel PG 13.5), 120 mm

24135140K

231512110

DIS sensor: gold ring, zircon junction, Tepox gel, S8 plug (swivel PG 13.5), 80 mm

24135130K

Zirkon® DIS (Ozone)

Zirkon® DIS is a potentiostatic sensor for measuring Ozone.

Benefits 

  • Low maintenance and robust 

  • Stable zero point 

  • Reliable measuring values 

  • Long operating life due to automatic sensor cleaning by ASR®

Applications
Disinfection
Drinking Water
Measuring Parameter
  • 0.. 1000 µg/l (ppb) 

  • 0.. 5.00/10.00 mg/l (ppm) 

 

Measuring parameter and range are defined by the connected Kuntze instrument or system.

 

 

Ambient Conditions
  • Max. pressure: 10 bar at 20 °C (145 psi at 68 °F) 

  • Min. conductivity: > 150 µS/cm , with ASR > 200 µS/cm  

  • Temperature: -5.. +70 °C  (23.. 158 °F)

Versions
Type/Configuration Description Article number

231612500

DIS sensor: 2 gold rings, zircon junctions, Tepox gel, M12 plug (swivel PG 13.5), 120 mm

24135140K

231512110

DIS sensor: gold ring, zircon junction, Tepox gel, S8 plug (swivel PG 13.5), 80 mm

24135130K

Zirkon® DIS (Hydrogen Peroxide)

Zirkon® DIS is a potentiostatic sensor for measuring Hydrogen Peroxide.

Benefits 

  • Low maintenance and robust 

  • Stable zero point 

  • Reliable measuring values 

  • Long operating life due to automatic sensor cleaning by ASR®

Applications
Disinfection
Drinking Water
Food & Beverage
Cooling Water
Measuring Parameter
  • 0.. 30.00 mg/l (ppm)

Ambient Conditions
  • Max. pressure: 10 bar at 20 °C (145 psi at 68 °F) 

  • Min. conductivity: > 150 µS/cm , with ASR > 200 µS/cm  

  • Temperature: -5.. +70 °C  (23.. 158 °F)

Versions
Type/Configuration Description Article number

231712500

DIS sensor: 2 platinum rings, zircon junction, Tepox gel, M12 plug (swivel PG13.5), 120 mm

24135260K

231212110

DIS sensor: platinum ring, zircon junction, Tepox gel, S8 plug (swivel PG 13.5), 80 mm

24135230K

Zirkon® DIS Pool
(Free Chlorine)

Zirkon® DIS Pool is a potentiostatic sensor for measuring Free Chlorine particularly in pool and spa applications.

Benefits 

  • Low maintenance and robust 

  • Stable zero point 

  • Reliable measuring values 

  • Long operating life due to automatic sensor cleaning by ASR®

Applications
Pool & Spa
Measuring Parameter
  • 0.. 1000 µg/l (ppb) 

  • 0.. 5.00/10.00 mg/l (ppm) 

  • 0.. 20.00 mg/l (ppm)

Ambient Conditions
  • Max. pressure: 10 bar at 20 °C (145 psi at 68 °F) 

  • Min. conductivity: > 150 µS/cm , with ASR > 200 µS/cm  

  • Temperature: -5.. +70 °C  (23.. 158 °F)

Versions
Type/Configuration Description Article number

237613500

DIS sensor: 2 gold rings, zircon junction, saturated KCl, M12 plug (swivel PG 13.5), 120 mm

24135145K

237513110

DIS sensor: 1 gold ring, zircon junction, saturated KCl, S8 plug (swivel PG13.5), 80 mm

24135288K

237813500

DIS sensor for brine: Platinum ring graphite pin,zircon junction, saturated KCl, M12 plug (swivel PG 13.5), 120 mm

24135150K

Zirkon® DIS Pool (Ozone)

Zirkon® DIS Pool is a potentiostatic sensor for measuring Ozone particularly in pool and spa applications.

Benefits 

  • Low maintenance and robust 

  • Stable zero point 

  • Reliable measuring values 

  • Long operating life due to automatic sensor cleaning by ASR® 

Applications
Pool & Spa
Measuring Parameter
  • 0.. 1000 µg/l (ppb) 

  • 0.. 5.00/10.00 mg/l (ppm)

Ambient Conditions
  • Max. pressure: 10 bar at 20 °C (145 psi at 68 °F) 

  • Min. conductivity: > 150 µS/cm , with ASR > 200 µS/cm  

  • Temperature: -5.. +70 °C  (23.. 158 °F)

Versions
Type/Configuration Description Article number

237613500

DIS sensor: 2 gold rings, zircon junction, saturated KCl, M12 plug (swivel PG 13.5), 120 mm

24135145K

Zirkon® DIS Pool (Hydrogen Peroxide)

Zirkon® DIS Pool is a potentiostatic sensor for measuring Hydrogen Peroxide particularly in pool and spa applic

Benefits 

  • Low maintenance and robust 

  • Stable zero point 

  • Reliable measuring values 

  • Long operating life due to automatic sensor cleaning by ASR®

Applications
Pool & Spa
Measuring Parameter
  • 0.. 30.00 mg/l (ppm)  

Ambient Conditions
  • Max. pressure: 10 bar at 20°C (145 psi at 68°F) 

  • Min. conductivity: > 150 µS/cm , with ASR > 200 µS/cm  

  • Temperature: -5.. +70 °C  (23.. 158°F)

Versions
Type/Configuration Description Article number

23791379K016

DIS-Sensor: 1 platinum ring and -plate, zircon junction, saturated KCl, 1.6 m fixed cable (swivel PG13.5 ), 155 mm

24135156K

237913990

DIS-Sensor: 1 platinum ring and -plate, zircon junction, saturated KCl, male socket (swivel PG13.5 ), 170 mm

24135155K